Reducing Data Center Energy Consumption
IT cares about energy efficiency, Pouchet said, but not if it affects performance and reliability. "Many IT shops are all for freeing up power and cooling capacity, as long as it does not impact performance and reliability." In the absence of a universal metric for data center output (like MPG for fuel efficiency), Pouchet said that discussing data center efficiency isn't meaningful. "We can only talk about reducing data center energy consumption." The company Pouchet works for, Emerson Network Power, modeled energy consumption for a typical 5,000-square-foot data center and analyzed how energy is used within the facility. Energy use was categorized as either "demand side" or "supply side." Demand-side systems are the servers, storage, communications, and other IT systems that support the business. Supply-side systems exist to support the demand side. In his analysis, demand-side systems -- which include processors, server power supplies, other server components, storage, and communication equipment -- account for 52% of total consumption. Supply-side systems include the UPS, power distribution, cooling, lighting, and building switchgear, and account for 48% of consumption. The distinction between demand and supply power consumption is useful because reductions in demand-side energy use cascade through the supply side. In Pouchet's 5,000-square-foot data center example, a 1-watt reduction at the server-component level (processor, memory, hard disk, etc.) results in an additional 1.84-watt savings in the power supply, power distribution system, UPS system, cooling system, etc. Consequently, every watt of savings that can be achieved on the processor level creates approximately 2.84 watts of savings for the overall facility. Using the model of a 5,000-square-foot data center that consumes 1,127 kW of power, Pouchet then walked through an approach that would combine to produce a 585-kW reduction in energy use. Pouchet also showed the payback period of various energy-saving strategies: 1. Lower power processors: 12 to 18 months Pouchet closed his talk by repeating his four key messages: 2. As you reduce energy consumption, make sure you do not compromise on availability and flexibility. 3. High-density architecture helps reduce energy consumption. 4. Even if efficiency isn't your key concern, implementing these strategies will free up power, cooling, and space capacity in your data center. For more information: Increasing requirements for processor cycles, memory, and storage as well as higher electricity demands mean your data center is consuming more power -- which means you're spending more -- every day. InformationWeek Analytics investigates and explains how to design a modular data center that will future-proof your investment. The report can be downloaded here. « Getting Started With: WordPress | Main | Intel's Awful Code Names » |
| Sign Up Now For InformationWeek News Alerts |