Google Researchers Propose Better Data Center Network

Thomas Claburn
Editor-at-Large

By configuring data center networks to utilize energy in proportion to network traffic, Google researchers believe they can improve efficiency sixfold and save millions of dollars over several years.

Continuing its broad, longstanding effort to encourage energy-efficient computing, Google researchers have proposed a new approach to data center network design for large clusters (10,000+ servers) that could lead to significant energy and cost savings.


More Hardware Insights

Webcasts

More >>

White Papers

More >>

Reports

More >>

In "Energy Proportional Datacenter Networks," a paper published last month by Google researchers Dennis Abts, Peter Klausler, Hong Liu, Michael R. Marty, and Philip M. Wells, the authors suggest several ways to build data center networks that use power in proportion to the volume of data being transmitted, rather than running at high-power during periods of both high and low utilization.

"By operating the network links at a data rate in proportion to the offered traffic intensity, an energy proportional data center network can further improve on the energy savings offered by the flattened butterfly topology," the paper states. "Modern switch chips capable of congestion sensing and adaptive routing already have the essential ingredients to make energy-proportional communication viable for large-scale clusters."

This approach, the authors claim, "can reduce operating expenses for a large-scale cluster by up to $3M over a four-year lifetime."

Key to the researchers' vision is the use of a flattened butterfly network topology rather than the folded-Clos topology. The flattened butterfly configuration, the researchers claim, results in lower power at full utilization and is better suited for techniques that aim to increase the dynamic range of network power -- a comparison of power used while idle to power used during full utilization.

Comparing a cluster with a flattened butterfly network to a similarly configured folded-Clos network, with an assumed electricity rate of $0.07 per kW hour and an average Power Usage Effectiveness (PUE) rating of 1.6, the researchers state that the flattened butterfly topology alone should result in $1.6 million of energy savings over the four-year lifetime of the cluster.

Further energy savings are projected through dynamically tuning network links to match required performance.

The authors suggest there's an opportunity for makers of network switching chips to deliver products capable of energy-proportional switching. Presently, a network link configured for 2.5 Gb/s consumes 42% of the power of a link configured for 40 Gb/s. Properly optimized, the energy usage should be more like 6.25% when running at 2.5 Gb/s.

Virtualization and cloud computing have taken over the mantle of hottest technology that only a few years ago was held by unified communications, but that doesn’t mean it’s easy to align the cloud with UC--or any major initiative, for that matter. Download our report here (registration required).

Related Reading


Informationweek Discussions

Start the Discussion


InformationWeek encourages readers to engage in spirited, healthy debate, including taking us to task. However, InformationWeek moderates all comments posted to our site, and reserves the right to modify or remove any content that it determines to be derogatory, offensive, inflammatory, vulgar, irrelevant/off-topic, racist or obvious marketing/SPAM. InformationWeek further reserves the right to disable the profile of any commenter participating in said activities.